Please enable JavaScript to view this site.

Selectric Resources

Navigation: Homepage > Service Manual S241-5615-3 > Removal Procedures

Rotate Selection Differential Removal

Scroll Prev Top Next More

 

ROTATE SELECTION DIFFERENTIAL REMOVAL

 

1. Position the carrier to the far right.

2. Remove the left dust cover, platen, feed rolls and paper deflector.

3. Remove the machine from the bottom pan.

4. Disconnect the clevises and remove them from the selector latch links.

5. Remove the latch bail spring.

6. Remove the motor.

7. Remove the rotate latch springs.

8. Pull out the rotate links.

9. Disconnect the tilt differential spring.

10. Remove the upper guide bracket screws.

11. Remove the balance arm mounting stud.

12. Disconnect the negative 5 bail drive link from the right end of the balance arm.

13. Rotate the cycle shaft until the cam followers are on the low points of the cams.

14. Remove the rotate differential assembly.

15. The following adjustments should be checked after the rotate selection differential assembly is replaced:

 

a. Typehead homing

b. Rotate latch clearance

C. Rotate differential guides

d. Selector latch links